Feedback

Thoracic MRI in Pediatric Oncology: Feasibility and Image Quality of Post-Contrast Free-Breathing Radial 3D T1 Weighted Imaging

ORCID
0000-0002-8549-8754
Affiliation
Clinic for Radiology, University of Münster and University Hospital Münster, Albert-Schweitzer-Campus 1, Building A1, D-48149 Münster, Germany
Tischendorf, Patricia;
Affiliation
Clinic for Radiology, University of Münster and University Hospital Münster, Albert-Schweitzer-Campus 1, Building A1, D-48149 Münster, Germany
Künnemann, Marc-David;
ORCID
0000-0002-5734-9524
Affiliation
Clinic for Radiology, University of Münster and University Hospital Münster, Albert-Schweitzer-Campus 1, Building A1, D-48149 Münster, Germany
Krähling, Tobias;
Affiliation
Department of Anesthesiology, University of Münster and University Hospital Münster, Albert-Schweitzer-Campus 1, Building A1, D-48149 Münster, Germany
Lange, Jan Hendrik;
ORCID
0000-0002-6562-280X
Affiliation
Clinic for Radiology, University of Münster and University Hospital Münster, Albert-Schweitzer-Campus 1, Building A1, D-48149 Münster, Germany
Heindel, Walter;
Affiliation
Clinic for Radiology, University of Münster and University Hospital Münster, Albert-Schweitzer-Campus 1, Building A1, D-48149 Münster, Germany
Beck, Laura

Objectives : To compare the feasibility and image quality of a post-contrast free-breathing radial stack-of-stars 3D T1w turbo-field echo Dixon sequence (3D T1w VANE mDIXON) with a conventional cartesian breath-hold 3D T1w fast-field echo mDIXON sequence in pediatric oncology patients undergoing chest MRI. Methods : A total of 48 children (34 females; mean age 5.3 ± 3.7 years) underwent contrast-enhanced chest MRI, with 24 examined using the 3D T1w VANE mDIXON sequence and 24 with a conventional breath-hold 3D T1w mDIXON sequence. Image quality was independently assessed by three radiologists using a 5-point scale. Signal-to-noise ratio (SNR) was measured at two anatomical sites, a homogeneous paraspinal muscle region (SNR muscle ) and the liver apex (SNR liver ), while avoiding vessels and signal inhomogeneities. The presence of respiratory artifacts, total imaging time, and the need for general anesthesia or sedation were recorded. Interobserver agreement was determined using Fleiss’s kappa (ϰ), and mean SNR values were compared between groups using an independent samples t -test. Results : The 3D T1w VANE mDIXON sequence yielded significantly higher SNR muscle and SNR liver (530 ± 120; 570 ± 110 vs. 370 ± 110; 400 ± 90; p < 0.001), improved diagnostic image quality by approximately 25%, and reduced respiratory artifacts by about 23%. Interobserver agreement was almost perfect. Importantly, the need for general anesthesia was significantly reduced using the 3D T1w VANE mDIXON ( p < 0.001). Conclusions : Free-breathing 3D T1w VANE mDIXON chest MRI is a feasible and effective imaging approach for pediatric oncology patients, offering superior image quality and reducing the need for general anesthesia compared to conventional methods.

Cite

Citation style:
Could not load citation form.

Access Statistic

Total:
Downloads:
Abtractviews:
Last 12 Month:
Downloads:
Abtractviews:

Rights

License Holder: © 2025 by the authors.

Use and reproduction: