Combining Electrostimulation with Impedance Sensing to Promote and Track Osteogenesis within a Titanium Implant

ORCID
0000-0002-6362-9282
Affiliation
Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, Rostock University Medical Center, Schillingallee 35, 18057 Rostock, Germany
Engel, Nadja;
ORCID
0000-0002-2619-3256
Affiliation
Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, Rostock University Medical Center, Schillingallee 35, 18057 Rostock, Germany
Dau, Michael;
ORCID
0000-0002-5173-5969
Affiliation
Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, Rostock University Medical Center, Schillingallee 35, 18057 Rostock, Germany
Engel, Vivien;
Affiliation
Oscar Langendorff Institute of Physiology, Rostock University Medical Center, Gertrudenstrasse 9, 18057 Rostock, Germany
Franz, Denise;
Affiliation
Institute of Physics, University of Rostock, Albert-Einstein-Str. 23-24, 18059 Rostock, Germany
Klemmstein, Fabian;
Affiliation
ibidi GmbH, Lochhamer Schlag 11, 82166 Gräfelfing, Germany
Thanisch, Christiane;
ORCID
0000-0002-0434-5001
Affiliation
Institute of Physics, University of Rostock, Albert-Einstein-Str. 23-24, 18059 Rostock, Germany
Kolb, Jürgen F.;
ORCID
0000-0002-2517-4440
Affiliation
Medical Biology and Electron Microscopy Centre, University Medical Center Rostock, Strempelstraße 14, 18057 Rostock, Germany
Frank, Marcus;
ORCID
0000-0001-9878-7240
Affiliation
Medical Biology and Electron Microscopy Centre, University Medical Center Rostock, Strempelstraße 14, 18057 Rostock, Germany
Springer, Armin;
ORCID
0000-0003-3330-4898
Affiliation
Oscar Langendorff Institute of Physiology, Rostock University Medical Center, Gertrudenstrasse 9, 18057 Rostock, Germany
Köhling, Rüdiger;
Affiliation
Department of Orthopedics, Rostock University Medical Center, Doberaner Str. 142, 18057 Rostock, Germany
Bader, Rainer;
Affiliation
Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, Rostock University Medical Center, Schillingallee 35, 18057 Rostock, Germany
Frerich, Bernhard;
ORCID
0000-0001-5661-6953
Affiliation
Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Center Mainz, Augustusplatz 2, 55131 Mainz, Germany
Wiesmann, Nadine;
Affiliation
Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Center Mainz, Augustusplatz 2, 55131 Mainz, Germany
Heimes, Diana;
ORCID
0000-0002-1671-3764
Affiliation
Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Center Mainz, Augustusplatz 2, 55131 Mainz, Germany
Kämmerer, Peer W.

(1) Background: Electrical stimulation is a promising alternative to promote bone fracture healing but with the limitation of tracking the osteogenesis progress in vivo. To overcome this issue, we present an opportunity to combine the electrical stimulation of a commercial titanium implant, which promotes osteogenesis within the fracture, with a real-time readout of the osteogenic progress by impedance sensing. This makes it possible to adjust the electrical stimulation modalities to the individual patient’s fracture healing process. (2) Methods: In detail, osteogenic differentiation of several cell types was monitored under continuous or pulsatile electrical stimulation at 0.7 V AC/20 Hz for at least seven days on a titanium implant by electric cell-substrate impedance sensing (ECIS). For control, chemical induction of osteogenic differentiation was induced. (3) Results: The most significant challenge was to discriminate impedance changes caused by proliferation events from those initiated by osteogenic differentiation. This discrimination was achieved by remodeling the impedance parameter Alpha (α), which increases over time for pulsatile electrically stimulated stem cells. Boosted α-values were accompanied by an increased formation of actin stress fibers and a reduced expression of the focal adhesion kinase in the cell periphery; morphological alterations known to occur during osteogenesis. (4) Conclusions: This work provided the basis for developing an effective fracture therapy device, which can induce osteogenesis on the one hand, and would allow us to monitor the induction process on the other hand.

Cite

Citation style:
Could not load citation form.

Access Statistic

Total:
Downloads:
Abtractviews:
Last 12 Month:
Downloads:
Abtractviews:

Rights

License Holder: © 2023 by the authors.

Use and reproduction: